St. Jude Medical Recalls
73 recalls on record · January 9, 2013 to April 2, 2025 · Medical Devices
Recalls by year
13
14
15
16
17
18
19
23
24
25
Count of recall notices naming this brand, by the year the recall was announced. A quiet year is not proof of a safe year.
March 25, 2015Medical DevicesFDA
St Jude Medical recalls TactiSys Quartz Pack, PN-004 400. For percutaneous catheter radiofrequency (RF) ablation of atrial cardiac arrhythm
Hazard: A configuration update needs to be done on TactiSys to appropriately recognize all TactiCath catheters.
November 12, 2014Medical DevicesFDA
St Jude Medical recalls St. Jude Medical, Fixed Curve Response 6F Electrophysiology Catheter, CSL, Model 401353
Hazard: St. Jude Medical is performing a voluntary recall of batch 4671318, model number 401353 of the Response Fixed Curve DECA 6F 65cm CSL 2/8 Catheter. Specifically, the firm has identified that every device packaged within batch 4671318 contains the incorrect catheter (Supreme FC QUAD 5F catheter) within the packaging. To date, no serious injuries have occurred as a result of this issue
October 29, 2014Medical DevicesFDA
St Jude Medical recalls St Jude Medical, 10F Fast-Cath Trio" Hemostasis Introducer, REF # 406308, Sterile EO. The Fast-Cath Trio" Hemostasis
Hazard: St. Jude Medical is conducting a voluntary recall of SMJ Batch # 4641580 of the Fast-Cath Trio" Hemostasis Introducer, Catalog number 406308. The inner diameter of the 10F dilator is too small, such that the guidewire cannot advance through the device which may result in a procedural delay while another dilator of the desired size is obtained.
October 8, 2014Medical DevicesFDA
St. Jude Medical, Inc. recalls Percutaneous Trial Lead Kit Model 3086 (8 ch percutaneous lead). Used as part of the St. Jude Medical Neurostimulatio
Hazard: The Directions for Use (DFU) manual contains information for devices that are not approved in the US. The correct US approved versions of the manuals were sent to the customers to replace the incorrect international manuals.
October 8, 2014Medical DevicesFDA
St. Jude Medical, Inc. recalls Percutaneous Trial Lead Kit Model 3046 (4 ch percutaneous lead). Used as part of the St. Jude Medical Neurostimulatio
Hazard: The Directions for Use (DFU) manual contains information for devices that are not approved in the US. The correct US approved versions of the manuals were sent to the customers to replace the incorrect international manuals.
November 20, 2013Medical DevicesFDA
St. Jude Medical recalls Safire Duo Ablation Catheter MediGuide Enabled, REF A700240 and A700238, Rx only, Sterile EO. Intended for creating e
Hazard: St. Jude Medical Cardiovascular and Ablation Technologies Division is performing a voluntary notification regarding selected batched of Safire Duo Ablation Catheter MediGuide Enabled. These units have a cable connector configuration that is different than intended.
November 13, 2013Medical DevicesFDA
St. Jude Medical recalls US Safire Duo Ablation Catheter MediGuide Enabled, REF A700240 and Cool Path Duo Ablation Catheter, MediGuide Enabled RE
Hazard: St. Jude Medical Cardiovascular and Ablation Technologies Division is performing a voluntary notification regarding selected batches of Coolpath Duo Ablation Catheter MediGuide Enabled products and Safire Duo Ablation Catheter MediGuide Enabled. These units were inadvertently shipped with the incorrect version of the Instructions for Use (IFU).
August 7, 2013Medical DevicesFDA
St. Jude Medical recalls Eon Mini - 3788 (IPG), Eon Mini system is indicated as an aid in the management of chronic intractable pain of the t
Hazard: As part of St. Jude Medical's routine tracking and product monitoring, they have received a total of 214 reports, out of 34,617 Eon Mini IPGs, that lost the ability to communicate or recharge due to an inner battery weld issue resulting in loss of pain relief and subsequent explant. Explant surgery, as with any surgery, presents a risk to patient health. Adverse events associated with an unplanne
July 31, 2013Medical DevicesFDA
St. Jude Medical recalls Eon and Eon Mini charging system, model numbers Eon -3701 (Wall Charger), 3711 (Portable Charger) and Eon Mini -3721 (Ch
Hazard: There is issues of warmth or heating at the implant site during charging for the Eon Mini implantable pulse generators (IPGs). In the July 2012 letter St. Jude Medical informed customers that they would be implementing design improvements to the charger to address possible increased energy dissipation when the charger is misaligned with the IPG or the IPG is implanted too near the surface of the
July 24, 2013Medical DevicesFDA
St. Jude Medical recalls Eon Mini - 3721 (Charger). Product Usage: Eon Mini system is indicated as an aid in the management of chronic intr
Hazard: St. Jude Medical has informed your doctor that a number of cases have been reported in which discomfort associated with heating occurred at the device site while patients were using the Charging System to charge their spinal cord stimulator. In three cases, patients received a burn to the skin (one second-degree and two first-degree burns) at the implant site. As of June 30, 2012, St. Jude Medica
July 24, 2013Medical DevicesFDA
St. Jude Medical recalls Eon - 3701 (Wall Charger) and 3711 (Portable Charger). Product Usage: Eon: Eon system is indicated as an aid in th
Hazard: St. Jude Medical has informed your doctor that a number of cases have been reported in which discomfort associated with heating occurred at the device site while patients were using the Charging System to charge their spinal cord stimulator. In three cases, patients received a burn to the skin (one second-degree and two first-degree burns) at the implant site. As of June 30, 2012, St. Jude Medica
February 20, 2013Medical DevicesFDA
St Jude Medical Inc recalls St. Jude Medical, AGA Medical corporation, AMPLATZER¿ TorqVue¿ FX Delivery System. Model #'s: 9-ITVFX06F45/60, 9-ITVFX07
Hazard: The distal end of the core wire of the TorqVue FX Delivery System could potentially fracture when exposed to a combination of certain cardiac anatomies and usage conditions.
January 9, 2013Medical DevicesFDA
St Jude Medical Inc recalls Fast-Cath Transseptal Guiding Introducer, 90, 8F, REF 406586, Length 60 cm, Sterile EO, Rx only, St. Jude Medical, 14901
Hazard: St. Jude Medical is recalling a single batch of Fast Cath Transseptal Guiding Introducers which was packaged as a 180 degree curve style introducer instead of a 90 degree curve style introducer as indicated on the labeling.