February 7, 2024Medical DevicesFDA
American Contract Systems, Inc. recalls Custom procedural convenience kits and trays, gastroenterological & urological, labeled as: a) LAP KIDNEY MODULE, kit
Hazard: During an internal investigation, ACS identified that several components were "piggybacked" to ACS trays and subjected to the ACS sterilization process. There is no supporting documentation stating the "piggybacked" components were assessed to determine if they were suitable for exposure to elevated temperatures for an extended period of time and further exposure to sterilization. As a result, the piggybacked components may (1) have a loss/lack of functionality, (2) loss of drug efficacy, if applicable, and (3) may have had higher than specified EO residuals.
February 7, 2024Medical DevicesFDA
American Contract Systems, Inc. recalls Custom procedural convenience kits and trays, gastroenterological & urological, labeled as: AHN BIOPSY STERILE, kit n
Hazard: During an internal investigation, ACS identified that several components were "piggybacked" to ACS trays and subjected to the ACS sterilization process. There is no supporting documentation stating the "piggybacked" components were assessed to determine if they were suitable for exposure to elevated temperatures for an extended period of time and further exposure to sterilization. As a result, the piggybacked components may (1) have a loss/lack of functionality, (2) loss of drug efficacy, if applicable, and (3) may have had higher than specified EO residuals.
February 7, 2024Medical DevicesFDA
American Contract Systems, Inc. recalls Custom procedural convenience kits and trays, ear, nose & throat, labeled as: a) T AND A PACK AGH ASC, kit number AGT
Hazard: During an internal investigation, ACS identified that several components were "piggybacked" to ACS trays and subjected to the ACS sterilization process. There is no supporting documentation stating the "piggybacked" components were assessed to determine if they were suitable for exposure to elevated temperatures for an extended period of time and further exposure to sterilization. As a result, the piggybacked components may (1) have a loss/lack of functionality, (2) loss of drug efficacy, if applicable, and (3) may have had higher than specified EO residuals.
February 7, 2024Medical DevicesFDA
American Contract Systems, Inc. recalls Custom procedural convenience kits and trays, cardiac, labeled as: a) CENTRAL LINE INSERTION PACK, kit number LLCE52;
Hazard: During an internal investigation, ACS identified that several components were "piggybacked" to ACS trays and subjected to the ACS sterilization process. There is no supporting documentation stating the "piggybacked" components were assessed to determine if they were suitable for exposure to elevated temperatures for an extended period of time and further exposure to sterilization. As a result, the piggybacked components may (1) have a loss/lack of functionality, (2) loss of drug efficacy, if applicable, and (3) may have had higher than specified EO residuals.
February 7, 2024Medical DevicesFDA
American Contract Systems, Inc. recalls Procedural convenience kits and trays, cardiac, labeled as: a) EP LAB BI V IMPLANT PACK, kit number AGBI64J; b) LAB
Hazard: During an internal investigation, ACS identified that several components were "piggybacked" to ACS trays and subjected to the ACS sterilization process. There is no supporting documentation stating the "piggybacked" components were assessed to determine if they were suitable for exposure to elevated temperatures for an extended period of time and further exposure to sterilization. As a result, the piggybacked components may (1) have a loss/lack of functionality, (2) loss of drug efficacy, if applicable, and (3) may have had higher than specified EO residuals.
February 7, 2024Medical DevicesFDA
American Contract Systems, Inc. recalls Custom procedural convenience kits and trays, cardiac, labeled as: a) HEART CATHETERIZATION TRAY, kit number JRHC45G;
Hazard: During an internal investigation, ACS identified that several components were "piggybacked" to ACS trays and subjected to the ACS sterilization process. There is no supporting documentation stating the "piggybacked" components were assessed to determine if they were suitable for exposure to elevated temperatures for an extended period of time and further exposure to sterilization. As a result, the piggybacked components may (1) have a loss/lack of functionality, (2) loss of drug efficacy, if applicable, and (3) may have had higher than specified EO residuals.
February 7, 2024Medical DevicesFDA
American Contract Systems, Inc. recalls Custom procedural convenience kits and trays, anesthesia, labeled as: a) HEART ANESTHESIA BUNDLE NS, Kit Number LMHA0
Hazard: During an internal investigation, ACS identified that several components were "piggybacked" to ACS trays and subjected to the ACS sterilization process. There is no supporting documentation stating the "piggybacked" components were assessed to determine if they were suitable for exposure to elevated temperatures for an extended period of time and further exposure to sterilization. As a result, the piggybacked components may (1) have a loss/lack of functionality, (2) loss of drug efficacy, if applicable, and (3) may have had higher than specified EO residuals.
February 7, 2024Medical DevicesFDA
Datex-Ohmeda, Inc. recalls EvAir CPRSR Kit Upgrade: a) DISS/CEE 7/7 230V 50/60 HZ, Model Number M1230849; b) DISS/NEMA 5-15 115V 60 HZ, Model
Hazard: GE HealthCare has become aware of elevated levels of formaldehyde when the EVair or EVair 03 (Jun-Air) optional compressors are used with the CARESCAPE R860 or Engstr¿m Carestation/Pro ventilators, respectively. These elevated results were observed in preliminary testing that was conducted at an elevated room temperature of 40oC (104oF), at the lowest possible flow condition of 2 L/min (worstcase, minimum bias flow with no additional ventilation), and all of the gas being supplied from the compressor (i.e., FiO2 of 21% / no supplemental oxygen). GE HealthCare is continuing to evaluate the root cause for these elevated levels of formaldehyde. While these test conditions are not representative of typical clinical use conditions,GE HealthCare is taking this action to further reduce the potential for patient exposure.
February 7, 2024Medical DevicesFDA
Datex-Ohmeda, Inc. recalls EVair 03 (Jun-air) air compressor, model numbers: 1609000 and 1609002
Hazard: GE HealthCare has become aware of elevated levels of formaldehyde when the EVair or EVair 03 (Jun-Air) optional compressors are used with the CARESCAPE R860 or Engstr¿m Carestation/Pro ventilators, respectively. These elevated results were observed in preliminary testing that was conducted at an elevated room temperature of 40oC (104oF), at the lowest possible flow condition of 2 L/min (worstcase, minimum bias flow with no additional ventilation), and all of the gas being supplied from the compressor (i.e., FiO2 of 21% / no supplemental oxygen). GE HealthCare is continuing to evaluate the root cause for these elevated levels of formaldehyde. While these test conditions are not representative of typical clinical use conditions,GE HealthCare is taking this action to further reduce the potential for patient exposure.
February 7, 2024Medical DevicesFDA
Datex-Ohmeda, Inc. recalls EVair air compressor, model numbers: M1230849 and M1230847
Hazard: GE HealthCare has become aware of elevated levels of formaldehyde when the EVair or EVair 03 (Jun-Air) optional compressors are used with the CARESCAPE R860 or Engstr¿m Carestation/Pro ventilators, respectively. These elevated results were observed in preliminary testing that was conducted at an elevated room temperature of 40oC (104oF), at the lowest possible flow condition of 2 L/min (worstcase, minimum bias flow with no additional ventilation), and all of the gas being supplied from the compressor (i.e., FiO2 of 21% / no supplemental oxygen). GE HealthCare is continuing to evaluate the root cause for these elevated levels of formaldehyde. While these test conditions are not representative of typical clinical use conditions,GE HealthCare is taking this action to further reduce the potential for patient exposure.
January 31, 2024Medical DevicesFDA
Diasorin Inc. recalls DiaSorin LIAISON HSV-2 Type Specific IgG, REF 310620
Hazard: DiaSorin has identified that lots 136344, 136344A, 136344B, 136344C, 136520, 136520A, 136520B, 136520C, 136604, 136703, 136703A, 136703B, 136703C 136775of LIAISON HSV-2 Type Specific IgG assay may produce increased equivocal and/or false positive results.
January 31, 2024Medical DevicesFDA
St. Jude Medical, Atrial Fibrillation Division, Inc. recalls TactiFlex Ablation Sensor Enabled Ablation Catheter, Models A-TFSE-FJ, 7.5 F shaft and an 8F distal section, Sterile.
Hazard: When the catheters are used with the EnSiteX EP System, the system does not correctly recognize the catheter as the appropriate product model and instead reads and displays it as a different model. This results in some features specific to the catheter do not appear on the display and the catheter image may also appear inverted.
January 31, 2024Medical DevicesFDA
B-K Medical A/S recalls bkActiv Ultrasound System 2300, Model numbers 2300-56 and 2300-66.
Hazard: An issue on the Dual Live Compare feature on the bkActiv system could result in a measurement error.
January 31, 2024Medical DevicesFDA
Philips North America recalls SmartPath to dStream for 1.5T, Model No. 781260, 782112
Hazard: An incorrect electrical shock warning label may have been placed on the Liquid Cooling Cabinet (LCC) of affected MR systems. The caution symbol on the incorrect label has a white background instead of yellow, and the label is missing the high voltage warning symbol. This presents a potential risk of electrical shock for service personnel.
January 31, 2024Medical DevicesFDA
Philips North America recalls Intera 1.5T, Model No. 781195
Hazard: An incorrect electrical shock warning label may have been placed on the Liquid Cooling Cabinet (LCC) of affected MR systems. The caution symbol on the incorrect label has a white background instead of yellow, and the label is missing the high voltage warning symbol. This presents a potential risk of electrical shock for service personnel.
January 31, 2024Medical DevicesFDA
Philips North America recalls Ingenia Ambition X, Model No. 782109
Hazard: An incorrect electrical shock warning label may have been placed on the Liquid Cooling Cabinet (LCC) of affected MR systems. The caution symbol on the incorrect label has a white background instead of yellow, and the label is missing the high voltage warning symbol. This presents a potential risk of electrical shock for service personnel.
January 31, 2024Medical DevicesFDA
Philips North America recalls Achieva 3.0T, Model No. 781177
Hazard: An incorrect electrical shock warning label may have been placed on the Liquid Cooling Cabinet (LCC) of affected MR systems. The caution symbol on the incorrect label has a white background instead of yellow, and the label is missing the high voltage warning symbol. This presents a potential risk of electrical shock for service personnel.
January 31, 2024Medical DevicesFDA
Philips North America recalls Achieva 1.5T Conversion, Model No. 781283
Hazard: An incorrect electrical shock warning label may have been placed on the Liquid Cooling Cabinet (LCC) of affected MR systems. The caution symbol on the incorrect label has a white background instead of yellow, and the label is missing the high voltage warning symbol. This presents a potential risk of electrical shock for service personnel.
January 31, 2024Medical DevicesFDA
Philips North America recalls Achieva 1.5T, Model No. 781178, 781196, 781296
Hazard: An incorrect electrical shock warning label may have been placed on the Liquid Cooling Cabinet (LCC) of affected MR systems. The caution symbol on the incorrect label has a white background instead of yellow, and the label is missing the high voltage warning symbol. This presents a potential risk of electrical shock for service personnel.
January 31, 2024Medical DevicesFDA
C.R. Bard Inc recalls Bard¿ Suction Connector with ENFit, REF EN0066000
Hazard: BD (C.R. Bard) has received user complaints reporting that during use of BD Bard NG Sump Tubes with ENFit Connectors, inadequate or reduced suction, decompression, and drainage occurred.
January 31, 2024Medical DevicesFDA
C.R. Bard Inc recalls Bard¿ Nasogastric Sump Tube and PreVent¿ Anti-Reflux Filter and Lopez Valve¿ with ENFit, 18Fr., 48in Long, REF EN0056180
Hazard: BD (C.R. Bard) has received user complaints reporting that during use of BD Bard NG Sump Tubes with ENFit Connectors, inadequate or reduced suction, decompression, and drainage occurred.
January 31, 2024Medical DevicesFDA
C.R. Bard Inc recalls Bard¿ Nasogastric Sump Tube and PreVent¿ Filter and Lopez Valve¿ with ENFit, 16Fr., 48in Long , REF EN0056160
Hazard: BD (C.R. Bard) has received user complaints reporting that during use of BD Bard NG Sump Tubes with ENFit Connectors, inadequate or reduced suction, decompression, and drainage occurred.
January 31, 2024Medical DevicesFDA
C.R. Bard Inc recalls Bard¿ Nasogastric Sump Tube and PreVent¿ Filter and Lopez Valve¿ with ENFit, 14Fr., 48in Long, REF EN0056140
Hazard: BD (C.R. Bard) has received user complaints reporting that during use of BD Bard NG Sump Tubes with ENFit Connectors, inadequate or reduced suction, decompression, and drainage occurred.
January 31, 2024Medical DevicesFDA
C.R. Bard Inc recalls Bard¿ Nasogastric Sump Tube and PreVent¿ Anti-Reflux Filter and Lopez Valve¿ with ENFit, 12Fr., 48in Long, REF EN0056120
Hazard: BD (C.R. Bard) has received user complaints reporting that during use of BD Bard NG Sump Tubes with ENFit Connectors, inadequate or reduced suction, decompression, and drainage occurred.
January 31, 2024Medical DevicesFDA
C.R. Bard Inc recalls Bard¿ Lopez Valve¿ with ENFit, REF EN0056000
Hazard: BD (C.R. Bard) has received user complaints reporting that during use of BD Bard NG Sump Tubes with ENFit Connectors, inadequate or reduced suction, decompression, and drainage occurred.
January 31, 2024Medical DevicesFDA
C.R. Bard Inc recalls Bard¿ Nasogastric Sump Tube with PreVent¿ Anti-Reflux Filter with ENFit, 18Fr., 48in Long, REF EN0046180
Hazard: BD (C.R. Bard) has received user complaints reporting that during use of BD Bard NG Sump Tubes with ENFit Connectors, inadequate or reduced suction, decompression, and drainage occurred.
January 31, 2024Medical DevicesFDA
C.R. Bard Inc recalls Bard¿ Nasogastric Sump Tube with PreVent¿ Anti-Reflux Filter with ENFit, 16Fr., 48in Long, REF EN0046160
Hazard: BD (C.R. Bard) has received user complaints reporting that during use of BD Bard NG Sump Tubes with ENFit Connectors, inadequate or reduced suction, decompression, and drainage occurred.
January 31, 2024Medical DevicesFDA
C.R. Bard Inc recalls Bard¿ Nasogastric Sump Tube with PreVent¿ Anti-Reflux Filter with ENFit, 14Fr., 48in Long, REF EN0046140
Hazard: BD (C.R. Bard) has received user complaints reporting that during use of BD Bard NG Sump Tubes with ENFit Connectors, inadequate or reduced suction, decompression, and drainage occurred.
January 31, 2024Medical DevicesFDA
C.R. Bard Inc recalls Bard¿ Nasogastric Sump Tube with PreVent¿ Anti-Reflux Filter with ENFit", 12Fr., 48in Long, REF EN0046120
Hazard: BD (C.R. Bard) has received user complaints reporting that during use of BD Bard NG Sump Tubes with ENFit Connectors, inadequate or reduced suction, decompression, and drainage occurred.
January 31, 2024Medical DevicesFDA
C.R. Bard Inc recalls Bard¿ Nasogastric Sump Tube with PreVent¿ Anti-Reflux Filter with ENFit, 10Fr., 36in Long, REF EN0046100
Hazard: BD (C.R. Bard) has received user complaints reporting that during use of BD Bard NG Sump Tubes with ENFit Connectors, inadequate or reduced suction, decompression, and drainage occurred.