July 12, 2023Medical DevicesFDA
Full Vision Inc recalls TRACKMASTER, TREADMILL GE T2100-ST2 220V CHINA, MODEL NUMBER 317-07927GE CHINA
Hazard: Treadmill malfunction: drive PCB can misread the signals and stop or reverse and then accelerate forward.
July 12, 2023Medical DevicesFDA
Full Vision Inc recalls TRACKMASTER, TREADMILL GE T2100-ST2 220V, MODEL NUMBER 317-07927GE
Hazard: Treadmill malfunction: drive PCB can misread the signals and stop or reverse and then accelerate forward.
July 12, 2023Medical DevicesFDA
Full Vision Inc recalls TRACKMASTER, TREADMILL GE T2100-ST1 110VV, MODEL NUMBER 317-07926GE
Hazard: Treadmill malfunction: drive PCB can misread the signals and stop or reverse and then accelerate forward.
July 12, 2023Medical DevicesFDA
Full Vision Inc recalls TRACKMASTER, TREADMILL TMX428CP 220V, MODEL NUMBER 317-07929
Hazard: Treadmill malfunction: drive PCB can misread the signals and stop or reverse and then accelerate forward.
July 12, 2023Medical DevicesFDA
Full Vision Inc recalls TRACKMASTER, TREADMILL TMX428CP 110V, MODEL NUMBER 317-07928
Hazard: Treadmill malfunction: drive PCB can misread the signals and stop or reverse and then accelerate forward.
July 12, 2023Medical DevicesFDA
Full Vision Inc recalls TRACKMASTER, TREADMILL TMX428 220V, MODEL NUMBER 317-07927
Hazard: Treadmill malfunction: drive PCB can misread the signals and stop or reverse and then accelerate forward.
July 12, 2023Medical DevicesFDA
Full Vision Inc recalls TRACKMASTER, TREADMILL TMX428 110V, MODEL NUMBER 317-07926
Hazard: Treadmill malfunction: drive PCB can misread the signals and stop or reverse and then accelerate forward.
December 14, 2022Medical DevicesFDA
Full Vision Inc recalls FULL VISION INC. TRACKMASTER, TREADMILL GE T2100-ST2 220V, Model #317-07927GE CHINA
Hazard: This has been identified a rare occurrence, under a specific scenario, where the circuit is found in a latch-up condition on the PCB that controls the safety function of the Magnetic Safety Tether, that when the magnet is pulled loose as during a fall, the treadmill may fail to stop.
December 14, 2022Medical DevicesFDA
Full Vision Inc recalls FULL VISION INC. TRACKMASTER, TREADMILL GE T2100-ST2 220V, Model #317-07927GE
Hazard: This has been identified a rare occurrence, under a specific scenario, where the circuit is found in a latch-up condition on the PCB that controls the safety function of the Magnetic Safety Tether, that when the magnet is pulled loose as during a fall, the treadmill may fail to stop.
December 14, 2022Medical DevicesFDA
Full Vision Inc recalls FULL VISION INC. TRACKMASTER, TREADMILL GE T2100-ST1 110V, Model #317-07926GE
Hazard: This has been identified a rare occurrence, under a specific scenario, where the circuit is found in a latch-up condition on the PCB that controls the safety function of the Magnetic Safety Tether, that when the magnet is pulled loose as during a fall, the treadmill may fail to stop.
December 14, 2022Medical DevicesFDA
Full Vision Inc recalls FULL VISION INC. TRACKMASTER, TREADMILL TMX428CP 220V, Model #317-07929
Hazard: This has been identified a rare occurrence, under a specific scenario, where the circuit is found in a latch-up condition on the PCB that controls the safety function of the Magnetic Safety Tether, that when the magnet is pulled loose as during a fall, the treadmill may fail to stop.
December 14, 2022Medical DevicesFDA
Full Vision Inc recalls FULL VISION INC. TRACKMASTER, TREADMILL TMX428CP 110V, Model #317-07928
Hazard: This has been identified a rare occurrence, under a specific scenario, where the circuit is found in a latch-up condition on the PCB that controls the safety function of the Magnetic Safety Tether, that when the magnet is pulled loose as during a fall, the treadmill may fail to stop.
December 14, 2022Medical DevicesFDA
Full Vision Inc recalls FULL VISION INC. TRACKMASTER,TREADMILL TMX428 220V, Model #317-07927
Hazard: This has been identified a rare occurrence, under a specific scenario, where the circuit is found in a latch-up condition on the PCB that controls the safety function of the Magnetic Safety Tether, that when the magnet is pulled loose as during a fall, the treadmill may fail to stop.
December 14, 2022Medical DevicesFDA
Full Vision Inc recalls FULL VISION INC. TRACKMASTER, TREADMILL TMX428 110V, Model #317-07926
Hazard: This has been identified a rare occurrence, under a specific scenario, where the circuit is found in a latch-up condition on the PCB that controls the safety function of the Magnetic Safety Tether, that when the magnet is pulled loose as during a fall, the treadmill may fail to stop.