July 8, 2026Medical DevicesFDA
Hamilton Medical AG recalls IntelliCuff, Portable automatic cuff pressure controller REF: 951001
Hazard: Due to reported complaints, the cuff device may alarm with a "Cuff System Leakage" error. As a result, the motor may pump continuously and fail to maintain the cuff pressure set by the user.
July 8, 2026Medical DevicesFDA
Hamilton Medical AG recalls Breathing circuit set, coaxial: REF: 260127, 260128, 260167, 260168 used with HAMILTON-C1, HAMILTON-T1 and HAMILTON-MR1
Hazard: Ventilator coaxial breathing circuit may have, expiratory valve sets with membranes sticking to valve body, not detectable during pre-operative test, which will result in "exhalation obstructed " alarm, which may result in inadequate ventilation, oxygen desaturation. Advising: Prior to use, test lung action. If alarm occurs, expiratory valve set removal to overcome membrane adhesion or replacement
August 27, 2025Medical DevicesFDA
Hamilton Medical AG recalls Hamilton C6 REF 160021 (ESM Board PN 10144626 UDI-DI code: 76300028PN160021ZW Hamilton C6 is a ventilator intended t
Hazard: A mechanical defect on a printed circuit board (PCB) as a result of PCB separating process. This defect might cause the ventilator to either fail at startup (no patient involvement) or during the use of the device enter ambient state, resulting in an interruption of ventilation.
August 6, 2025Medical DevicesFDA
Hamilton Medical AG recalls Breathing circuit set, coaxial, 1.80 m, with flow sensor and expiratory valve set, REF: 260128, used with HAMILTON-C1, H
Hazard: Ventilator coaxial breathing circuit may have a crack in blue tubing, which is used to deliver fresh gas to the patient. The crack will compromise inspiratory and expiratory flows, leading to partial or complete rebreathing of exhaled gases, which could lead to acute hypercapnia, respiratory acidosis, and if unrecognized organ dysfunction.
June 26, 2024Medical DevicesFDA
Hamilton Medical AG recalls Ventilator HAMILTON-C6, PN: 160021
Hazard: Ventilator may enter sensor fail mode, ventilation may not re-initiate, after patient is reconnected, which may cause hypoxia, if this sequence occurs: 1)User presses O2 enrichment, 2)User disconnects endotracheal tube for open suctioning, 3)Sensor error initiated, sensor fail mode occurs, 4)Patient is re-connected with sensor fail mode active, 5) Ventilation is not re-initiated by the ventilator.
May 3, 2023Medical DevicesFDA
Hamilton Medical AG recalls HAMILTON-C6, REF: 160021
Hazard: Software error causes, safety ventilation, in which ventilation continues in the "safety ventilation" mode with audible/visible alarm - patient inputs are not monitored, if the following coincide 1) A mode change to an adaptive mode (ASV, APVcmv, APVsimv, INTELLiVENT-ASV, (S)CMV+, SIMV+), and 2) The controller and/or humidifier is connected to the ventilator and is operational.
November 30, 2022Medical DevicesFDA
Hamilton Medical AG recalls Hamilton-C6
Hazard: Due to a malfunction related to the backlight on the ventilator screen. The screen goes black for approximately 2-3 seconds, but it brightens up again when the backlight switches on again.
August 31, 2022Medical DevicesFDA
Hamilton Medical AG recalls HAMILTON-C6 Intensive Care Ventilator, REF: 160021
Hazard: Ventilator status indicator board can become loose, which could lead to water ingress (disinfectants) that may lead to technical fault alarms. Multiple technical faults in a short time may force ventilators into Safety Ventilation (blower runs constantly) or Ambient Sate (inspiratory channel/expiratory valves opened; patient breaths room air unassisted) with Panel connection lost message displayed
July 20, 2022Medical DevicesFDA
Hamilton Medical AG recalls HAMILTON-H900 Humidifier, Models: 950001, 950004
Hazard: When starting a humidifier, intended for respiratory gas conditioning during invasive and noninvasive mechanical ventilation, with an empty chamber, and water is not filled into the chamber, the low water level alarm will be delayed and medical staff are unaware that there is no water in the chamber.
July 17, 2019Medical DevicesFDA
Hamilton Medical AG recalls HAMILTON-G5, with software versions less than or equal to 2.60 The HAMILTON-G5/S1 ventilators are designed for intens
Hazard: New software version for affected ventilators reduces the probability of the ventilator entering an ambient state, in which the inspiratory channel and expiratory valves are opened, letting the patient breathe room air unassisted. When the ventilator enters the ambient state, alternative ventilation must be provided immediately.
August 22, 2018Medical DevicesFDA
Hamilton Medical AG recalls Hamilton-C3 Ventilator Unit Product Usage: The HAMILTON-C3 ventilator is intended to provide positive pressure venti
Hazard: An out of specification component on the control board may cause the ventilator to open the inspiratory channel and the expiratory valve. The ventilator will shut down and an emergency buzzer providing an acoustic alarm and the blinking alarm LED on the device s front side.
August 22, 2018Medical DevicesFDA
Hamilton Medical AG recalls Hamilton-C1 Ventilator Unit Product Usage: The HAMILTON-C1 ventilator is intended to provide positive pressure venti
Hazard: An out of specification component on the control board may cause the ventilator to open the inspiratory channel and the expiratory valve. The ventilator will shut down and an emergency buzzer providing an acoustic alarm and the blinking alarm LED on the device s front side.
April 18, 2018Medical DevicesFDA
Hamilton Medical AG recalls Hamilton-C3 Ventilator Unit Intended to provide ventilator support to adults and pediatrics and optionally infants an
Hazard: After two and a half years, the battery fuel gauge may indicate a higher battery charge than what is available.
April 18, 2018Medical DevicesFDA
Hamilton Medical AG recalls Hamilton-C2 Ventilator Unit Intended to provide ventilator support to adults and pediatrics and optionally infants an
Hazard: After two and a half years, the battery fuel gauge may indicate a higher battery charge than what is available.